Online Form - LMA SS

Linear Microelectrode Array (LMA) - Single Shank
× Fields marked with (*) are required
    Contact Information
  1. Principal Investigator name:(*)
    Please type your Principal Investigator name.
  2. Institution Name:(*)
    Please type your Institution name.
  3. Institution Address:
    Invalid Input
  4. Telephone Number:
    Invalid Input
  5. Email:
    Invalid email address.
  6. Researcher’s name:(*)
    Please type your Researcher’s name.
  7. Researcher’s email:(*)
    Please type your Researcher’s email.
  8. General Specifications
    Linear Microelectrode Arrays
    Outside Diameter in microns of the Polyimide Probe
      4 6 8 10 12 14 16 18 20 22 24
    12.5 µm 198 198 198 218 218 218 218 241 241 264 264
    25 µm 198 198 218 218 241 241 264 264 292 325 325
    37.5 µm 218 218 241 241 264 264 292 325 325 370 370
    50 µm 241 264 292 325 325 370 370 410 454 505 560
    Outside Diameter of the optional Stainless Steel
      4 8 16 24
    12.5 µm 0.016" OD 0.016" OD 0.018" OD 0.020" OD
    25 µm 0.016" OD 0.016" OD 0.018" OD 0.020" OD
    37.5 µm 0.016" OD 0.016" OD 0.020" OD 0.025" OD
    50 µm 0.016" OD 0.018" OD 0.025" OD 0.0335" OD
    Impedance value chart
    Diameter Impedance
    12.5 µm Pt/Ir 0.5 to 0.8 MΩ
    25.0 µm Pt/Ir 0.3 to 0.5 MΩ
    37.5 µm Pt/Ir 0.2 to 0.4 MΩ
    50.0 µm Pt/Ir 0.1 to 0.3 MΩ
    Typical Impedance @ 1 Kilohertz
    Design Specifications Model LMA-n-a-Y-b-c-d-X-Ref-Gr:
  9. 1. Metal type and electrode site diameter:(*)
    This field is required
  10. 2. n: Number of recording sites(*)
    Numeric value
    (4 to 24)
  11. 3.a: Length of the polyimide tube(*)
    Numeric value
    (mm) (25mm max or 15mm max for 12.5 µm wire)
  12. 4. c: Electrode size(*)
    Numeric value
    (µm) (determined by selection of wire diameter)
  13. 5. d: Distance between contacts(*)
    Invalid Input
    (µm)
  14. 6. X: Diameter of the polyimide tube(*)
    Numeric value
    (µm)
  15. 7. Y: Include additional rigid tube for extended length and support(*)
    This field is required
  16. Invalid Input
  17. b: Length of stainless steel or microfil tube(*)
    Invalid Input
  18. 8. Ref: Include a reference connection?(*)
    This field is required
  19. Invalid Input
  20. mm off the base of the connector
    Invalid Input
  21. Invalid Input
  22. 9. Gr: Include ground connection?(*)
    This field is required
  23. This field is required
  24. mm extending from the connector
    Invalid Input
  25. Invalid Input
  26. Your Custom Design and Layout Sheet

    Please upload your file with your custom specifications (if applicable):

  27. Upload a file:
    Invalid Input
    Allowed file types: bmp, gif, jpg, jpeg, png, doc.

  28. 11. Connector(s)(*)









    This field is required
  29. (provided by the customer)
    Invalid Input
  30. About your order
  31. How many of this LMA Single Shank design do you wish to order(*)
    Numeric Value
  32. Special requirements
    Invalid Input
  33. How did you find us?



    Invalid Input
  34. How should we contact you?