Online Form - Opto MWA

Opto Microwire Array [Opto-MWA]
The Opto Microwire Array (Opto-MWA) has been designed to take on many different geometries and electrode/fiber optic layouts for a multitude of experimental protocols.

Originally designed for chronic applications the MWAs are equally effective for acute studies as well. The number of contacts, length of each, the impedance and distance between electrodes are all custom designed.

× Fields marked with (*) are required
    Contact Information
  1. Principal Investigator name:(*)
    Please type your Principal Investigator name.
  2. Institution Name:(*)
    Please type your Institution name.
  3. Institution Address:
    Invalid Input
  4. Telephone Number:
    Invalid Input
  5. Email:
    Invalid email address.
  6. Researcher’s name:(*)
    Please type your Researcher’s name.
  7. Researcher’s email:(*)
    Please type your Researcher’s email.
  8. General Specifications
  9. 1. Metal type:(*)
    This field is required
  10.     Insulation type(*)
    This field is required
  11. 2. Wire Diameter:(*)
    This field is required
    Impedance Values per metal type and wire size
    Wire Diameter Range
    25 µn Platinum Iridium 0.4 to 0.8 MΩ
    50 µn Platinum Iridium 0.2 to 0.4 MΩ
    25 µn Stainless Steel 0.6 to 0.9 MΩ
    50 µn Stainless Steel 0.4 to 0.6 MΩ
  12. 3. Number of wires:(*)
    Numeric value
    (4 - 64)
  13. Physical Measurements
  14. 4. E: Epoxy length below connector: (*)
    This field is required
  15. Invalid Input
  16. 5. C Length of wire covered with carbowax (PEG)
    Invalid Input
  17. Numeric value
  18. 6. L: Length of electrode beyond carbowax:(*)
    This field is required
  19. Numeric value
    (Up to 35mm)
  20. 7. D Include an Epoxy Blob?
    Invalid Input
  21. Invalid Input
    D - reference in graphic
  22. 8. Es: Distance between electrodes:(*)
    This field is required
  23. Numneric value
    mm
  24. 9. Please select your layout
    Invalid Input
  25. Or make a drawing (top view) as clear as possible with all dimensions
  26. Upload a file:
    Invalid Input
    Allowed file types: bmp, gif, jpg, jpeg, png, doc.

  27. 10. Number of rows of electrodes(*)
    This field is required
  28. (*)
    Numeric value.
    (Up to 12 rows)
  29. 11. Rs: Distance between rows(*)
    This field is required
  30. Numeric value
    mm
  31. 12. Number of fiber optic in the array(*)
    This field is required.
  32. Invalid Input
  33. 13. Type of desired fiber optic and receptacle(*)



    This field is required.
  34. Invalid Input
  35. 14. HD: Horizontal distance from the edge of fiber optic and the closest electrodes(*)
    This field is required.
    (100 µm minimum)
    Horizontal distance from the edge of fiber optic and the closest electrodes
  36. 15. LF: Length of the fiber optic beyond epoxy
    This field is required.
    mm
     Length of the fiber optic beyond epoxy
  37. Recording channel pinout
    Channel Pinout Advertence
    To ensure your complete satisfaction, MicroProbes for Life Science will provide a photograph and copy of the pin layout mapping and corresponding microelectrodes, including reference and ground, with your shipped order.

    Connector pin assignments will reflect connector pin numbers NOT headstage channel numbers

    Your Custom Design and Layout Sheet

    16. Make drawing as clear as possible with all dimensions clearly labeled, including connector Manufacturer & Model #, if different from those specified below:

  38.       Upload a file:
    Invalid Input
    Allowed file types: bmp, gif, jpg, jpeg, png, doc.
  39. 17. Make a drawing (top view) as clear as possible with all dimensions clearly labeled about the fiber optic and the surrounding electrodes.

  40.       Upload a file:
    Invalid Input
    Allowed file types: bmp, gif, jpg, jpeg, png, doc.

  41. 18. Include a reference wire?(*)
    This field is required
  42. Invalid Input
  43. 19. Include a 5cm long Ground Wire? (*)
    This field is required
  44. Invalid Input
  45. 20. Number of connectors(*)
    Numeric value
    (up to 6 connectors)
  46. 21. Connector(s)(*)









    This field is required
  47. (provided by the customer)
    Invalid Input
  48. 22. R: Receptacle edge/Connector edge distance:
    This field is required.
    mm
    Receptacle edge - Connector edge distance
  49. About your order
  50. How many opto-MWA design do you wish to order(*)
    Numeric Value
  51. Special requirements
    Invalid Input
  52. How should we contact you?



  53. How did you find us?



    Invalid Input