Online Design Form - LMA - Multi Shank

Fields marked with (*) are required

Contact Information

Enter the Contact Person’s Name.
Enter a valid email.
Enter a valid phone number
Enter your Institution name.
Enter the Street, City, State, and Zip Code (If apply).
Enter the Principal Investigator’s name.
Please type Name on Quote (if not contact person)

General Specifications

The Multi-Shank LMA design is ideal for acute or chronic applications. Each shank can have up to 32 electrode sites, therefore multiple connectors may be needed. MicroProbes for Life Sciences may also employ the 36 contact Nano Omnetics connector, model A79022-001, which is also compatible with most headstage manufacturers.

You will need to specify the number of shanks (S) as well as the specifications associated with each prong. If no SS tube is required, which may be the case for chronic applications, then specify 0 for option (b).

Outside Diameter in microns of the Polyimide Probe
  4 6 8 10 12 14 16 18 20 22 24 32
12.5 µm 198 198 198 218 218 218 218 241 241 264 264 300
25 µm 198 198 218 218 241 241 264 264 292 325 325 375
37.5 µm 218 218 241 241 264 264 292 325 325 370 370  
50 µm 241 264 292 325 325 370 370 410 454 505 560  
Reference measurement: micron (µm)
Outside Diameter of the optional Stainless Steel
  4 8 16 24 32
12.5 µm 0.016" OD 0.016" OD 0.018" OD 0.020" OD 0.020" OD
25 µm 0.016" OD 0.016" OD 0.018" OD 0.020" OD 0.025" OD
37.5 µm 0.016" OD 0.016" OD 0.020" OD 0.025" OD  
50 µm 0.016" OD 0.018" OD 0.025" OD 0.0335" OD  
Any number of channels in between will use the larger diameter tubing. For example, a 12 channel LMA with 12.5um contact sites will use a 0.018" OD tubing.
Impedance value chart
Diameter Impedance
Typical Impedance @ 1 Kilohertz
12.5 µm Pt/Ir 0.5 to 0.8 MΩ
25.0 µm Pt/Ir 0.3 to 0.5 MΩ
37.5 µm Pt/Ir 0.2 to 0.4 MΩ
50.0 µm Pt/Ir 0.1 to 0.3 MΩ
LMA - Single Shank
LMA - Single Shank dimentions
  • a = Length of polyimide tube (15 mm max. for 12.5 µm wire)
  • b = Length of Stainless or Microfill Tube.
  • d = Distance between contacts.
  • n = Number of recording sites.
  • X = Diameter of polyimide tube (refer to the table 1).
  • Y = Diameter of Stainless Steel tube is approx. 50% larger than Polyimide tube.

Design Specifications

Model LMA-MS-n-a-Y-b-c-d-X-s-Rs-Ref-Gr
This field is required
Value out of range.
Invalid Input
Invalid Input
You can use numbers and periods.
You can use numbers and periods.
You can use numbers and periods.
You can use numbers and periods.
This field is required.
This field is required
You can use numbers and periods.
This field is required.
Invalid Input
Invalid Input
Invalid Input
This field is required.
This field is required
You can use numbers and periods.

Connector and Headstage

This field is required
Invalid Input
This field is required

Your custom design and layout sheet

If your requested design cannot be fully described by the questions above, please attach a description here. Make drawing as clear as possible:

Invalid Input

Accessories and Additional Services

Invalid Input

Application Description (Optional)

Invalid Input
Invalid Input
Invalid Input
Invalid Input

About Your Order

Numeric Value
See Terms and Conditions for details
Invalid Input
Invalid Input